Purpose
Radar data transmission unit (BPRD) TALM.465651.009 is
intended for radar and DF data monitoring and radar site
hardware (technical facilities) control signals
acquisition and for transmission of the received
information to the ATC control center automation
equipment via two leased tone frequency channels,
digital channels or physical lines.
Main functions
- Radar data receiving from one or two sets of
radar complex information plot extracting equipment
(APOI) with automatic switching to reception from
reserved APOI set in case of breakdown,
disconnection or main equipment setting to the
schedule mode;
- DF data receiving from one or several automatic
direction finders (ARP-75, ARP-80) interfaced with
ADC-DF or "PLATAN" ADF;
- Radar site equipment status messages and
(technical) control commands exchange with radar
site automation complex (RSAC) monitoring and
control equipment in RADUGA-2 RSAC unified
patterns;
- "PRIORITY-NORTH" signal receiving from RSAC
equipment and the respective pattern generation;
- All received data multiplexing in unified
patterns;
- Multiplexed data in PRIOR APOI / RADUGA2 RSAC / SINTEZ Area- terminal automated ATC system unified
patterns, ASTERIX protocol patterns, START APOI ATC
automation system distribution device pattern, SKALA
radar complex, APOI / STRELA Area-terminal System
unified patterns, "TERKAS" ATC Automated System
patterns or in any other coordinated with Customer
patterns transmission to the ATC control center
automation equipment via two direct tone frequency
channels (using external or internal modems),
digital channels and/or physical lines;
- Multiplexed data in PRIOR APOI / RADUGA2 RSAC / SINTEZ Area- terminal automated ATC system unified
patterns transmission to the monitoring and control
equipment remote control terminal via two direct
tone frequency channels (using external or internal
modems), digital channels and physical line;
- APOI equipment and self operation condition
diagnostics and indicating, input and output
circuits switching control signals generation;
- Multiplexed data delivery to the monitoring
display;
- Received and transmitted data delivery to the
IBM PC type computer.