Interface with
Radar Complex APOI, ACP-RP (ARP-75, ARP-80) and "PLATAN"
ADF: |
Interface type:
Data rate:
Transmission method:
Transmission mode: |
RS-232S EIA ( V.24 / V.28 ITU-T, C2 GOST 18145-81 )
9600 bps
serial asynchronous
simplex (BPRD - receiving) or duplex |
|
Interface with monitoring and control equipment
specifications: |
Interface type:
Data rate:
Transmission method:
Transmission mode: |
RS-232S EIA ( V.24 / V.28 ITU-T, C2 GOST 18145-81 )
9600 bps
serial asynchronous
duplex |
|
Interface with external modem (when transmitting via
tone frequency channel) and multiplexer (when
transmitting via digital channel) specifications : |
Interface type:
Data rate:
Transmission method:
Transmission mode: |
RS-232S EIA ( V.24 / V.28 ITU-T, C2 GOST 18145-81 )
2400, 4800 or 9600 bps
serial synchronous and asynchronous
simplex (BPRD- transmission) or duplex |
|
Interface with tone frequency channel (when using the
internal modem): |
Interface type:
Channel type
Data rate:
Transmission method:
Transmission mode: |
C1-TCH GOST 25007-81
standard four-wired
2400, 4800 or 9600 bps
serial synchronous or asynchronous
simplex (BPRD- transmission) or duplex |
|
Interface with physical line specification: |
Interface type:
Signal type:
Data rate:
Transmission method:
Transmission mode: |
C1-FL GOST 27373-84 and GOST 27232-87
bipulse
2400, 4800 or 9600 bps
serial synchronous
simplex (BPRD- transmission) or duplex |
|
Interface with monitor display and computer
specifications: |
Interface type:
Data rate:
Transmission method:
Transmission mode:
Semi-sets switch on/off control: |
RS-232S EIA ( V.24 / V.28 ITU-T, C2 GOST 18145-81 )
9600 bps
serial asynchronous
simplex (BPRD - transmission)
local, remote, automatic |
|
Power supply from one or two feeders of single-phase AC
power system |
Voltage, V
Frequency, Hz |
187÷242
50÷1 |
|
Consumed power, VA, no more than |
12.0 ( 20.0 when using internal modems ) |
|
Dimensions (depth x width x height) |
235 x 238 x 295 mm |
|
Weight, kg, no more |
6.0 ( 7.0 when using external modems ) |
|
MTBF, h, not less |
10 000 |
|
MTTR, h, no more |
0.5 |
|
Operation mode |
round-the-clock, continuous |
 |
 |