Main performance specifications
- Number of control objects - up to 15 (with
capability of expansion);
- Number of object status and operability signals
- up to 32 (with capability of expansion);
- Number of control commands for every object - up
to 16 (with capability of expansion and also with
capability of forming and transmitting the commands
for the objects groups);
- Maximum distance to control objects - 10 000 m;
- Cycle of information exchange with all operating
control objects - approximately 1 sec;
- Capability of an efficient reconfiguration of
the complex equipped with technical
supervisor automated working position;
- MTBF - not less, than 10 000 hours;
- Power supply - by 220 V, 50 Hz AC power supply
system or by +27V autonomous power supply system
and/or by +24V rechargeable battery;
- The communication channels in every direction to
the control object can be presented by:
- two cable physical lines;
- one physical line and radiochannel (radioline);
- Operation conditions:
- ambient temperature from -50°C up to +55°C (max
+65°C);
- relative humidity up to 98% at the ambient
temperature not higher, than + 25°C.
Design
BTsK unit is designed as "Uniset iS" in which
two semi-sets of boards are installed, each of them
contains central switch board and UP2 power supply
device board.
BIP is also divided for installation of two semi-sets of
boards, each of them contains the data transmission
device board (UPDT) and interfacing board (PS).
Adaptation capabilities
KDKU RTO has wide adaptation capabilities to the
operation conditions and the Customer requirements in
following specifications:
- number and type of control objects;
- realization of the objects servicing;
- operability and technical control commands set;
- design and equipment power supply;
- communication channels type and communication
channels net topology;
- supplementary facilities for providing the RTO
(radio technical equipment) operability information.